Add to Cart
Q SwitchedND YAG Laser eye line removal Machine / capillary hemangioma removal machine
Technology parameter
Laser type | Q-swiched ND YAG |
Wavelength | 1064nm/532nm |
Laser output method | Pulse electro-optic adjusting Q |
Pulse Duration | 8ns±2ns |
Output energy(generator) | 400~800mj(single),1000~1200mj(double) |
Spot diameter | 1-9mm adjustable |
Guiding beam arm | Seven-joints articulated arm |
Pulse rate | 1-10Hz |
Aiming beam | 650nm red diode laser |
Input voltage | AC220v,AC110v |
Cooling system | Water cooling+wind cooling |
Input power | 1200W |
Net weight | 80kg |
Dimension(cm) | 80*40*110cm |
Principle of Therapy
Therapy of epidermis and dermis pigmentation-------Utilizing the explosive effect of the Nd: YAG laser, the laser permeate the epidermis into the dermis which includes amount of pigment mass. Since the laser pulses in nanosecond but with super high energy, the shot pigment mass swell quickly and breaks into small pieces, which will be eliminated through metabolic system.
Therapy of the dilatation of capillary vessel-----Utilizing the heat effect of the Nd: Yag Laser, the laser is absorbed by the hemachrome in the capillary vessel, then the capillary vessel become blocked and disappear.
Maintenance
1.The system contains dedicate laser generator and electrical components. Heavily Shock and extrusion is not allowed when operating and storing the system. After each treatment, The joints arm should put on the original place. Use the dust-proof cloth to cover the system.
2.Clean the lens of the joints arm with the no water alcohol after each treatment. The lens is at the tip of the joints arm. Revolve the handle to joints arm can get the lens.Warning: Do not check and clean the lens when the system is on power.
Calibration of the specifications
3.The calibration of the output:
1)Turn on the system
2)Adjust the light guide system, make the laser pulse can direct at the centre of the reaction interface of the energy calibrator.
3)When the system is at WORK status, Choose lowest Frequency(1Hz) to test the energy of the output.
4.The main body contains input protective fuse to avoid the system destroyed by the over loaded high voltage and high current of the power supply.
The step of change the broken fuse: The fuse is at the back side of the main body. Loose the fuse cap and take off the broken fuse.
5.If the environmental temperature change too much, the explosive power will reduce, and at the same time, the thermal efficiency will increase. Then emit the laser to the printing paper. If there is smoke rise from the paper, the operator must ask the technician to check the optical-electrical switch.
6.When the error value between practical output and expected output is ≥±20%. The calibration
Specifications and performance Guideline
Environmental conditions
1. Temperature: 10℃~30℃
2. Relative humidity: ≤75%,Air pressure: 860-1060hpa,Power requirement: AC 220v±10%;50Hz±2%, Water: Distilled water
Laser Skin-care System
Pigmented lesion: Yiteng lentigines, Taitian Lentiines, freckles, eyebrow tattoo, body tattoo, lips tattoo.Vascular lesion: Pigment with red, brown, blue and black; vascular expanding
Pretreatment preparation
Make sure whether the clients’ skin is keloid skin, and learn whether they have purified their eyebrows, pigment with other means.
Explain to clientele that after riding of pigment still having pigment trace left which previously caused by sunburn.
Let clientele know that even after riding of the black and blue pigments still having brown and red left for the presence of composite painting material.
Better shave the client’s eyebrow for easy operating before the treatment.
Advantage
Components of the Unit Description
LCD screen :Show the work status and adjustable specifications.
Handrail :Protect the main body and move the machine in short distance.
Key switch :Turn on or turn off the system.
Emergency shut-off Knob:Turn off the system on emergency.
Joints arm:Transfer the light to the target area.
Transformer
Power supply socket :Connect with the power supply line plug.
Pedal switch socket :Connect with the pedal switch.
Foot Pedal: Control the output of laser emittance.
Environment requirement of installation and operation
The room should be clean and no dirty
Air conditioner, Voltage transformer and dust collector is necessary.
Transportation of the Device
The power supply, laser generator and joints arm should be paced separately with original shock proof package supplied by the manufacturer. Installation is only allowed on place by professional technician.
Installation of the system
Installation is only allowed on place by professional technician.
After installation finished, The technician must adjust and calibrate the display error, the exactness of the cursor, the diameter of the spot size, the single pulse energy and power supply.